| 120V Input Power | |||||
| # of zones | Standard Setup Model # | PC Setup Model # | Unit Capacity (Watts/VA) | Zone Capacity (Watts/VA) | Wallbox U.S. Size |
| 2 | GRX-3102 | GRX-3502 | 1200 | 800 | 2 Gang, 3.5" depth |
| 3 | GRX-3103 | GRX-3503 | 1500 | 800 | 3 Gang, 3.5" depth |
| 4 | GRX-3104 | GRX-3504 | 2000 | 800 | 4 Gang, 3.5" depth |
| 6 | GRX-3106 | GRX-3506 | 2000 | 800 | 4 Gang, 3.5" depth |
Top
GRAFIK Eye 4000 Series Control Unit
- Provides pushbutton recall of four preset lighting scenes, plus Off.
- Allows setup of lighting scenes using buttons on the Control Unit.
- Controls virtually any light source via dimming and switching panels.
- Provides lockout options to prevent accidental changes.
- Includes built-in infrared receiver for operation with an optional remote control.
- Control 2 to 24 zones lighting.
- GRAFIK Eye Wallstations
- GP and LP Dimming Panels
- XP Softswitch™ Panels
GRX-4100 Control Units Provide setup using buttons on the Control Unit.
GRX-4500 Control Units Provide optional setup using a PC, including setting lighting levels in 1% increments.
Specifications
Power- Low-voltage type Class 2 (PELV) Operating voltage: 24V Direct Current.
Controls lighting sources with a smooth, continuous Square Law dimming curve or on a full conduction non-dim basis via GP and LP Dimming Panels and XP Softswitch™ Panels.
Preset Control- 4 preset lighting scenes and off are accessible from the Control Unit front panel.
- 12 additional scenes are stored in the Control Unit. These scenes are accessible via Wallstations and/or Control Interfaces.
- Light levels fade smoothly between scenes. Fade time can be set differently for each scene, between 0-59 sec. or 1-60 min. Fade time from Off is capped at 5 sec.
- Meets IEC 801-2. Tested to withstand 15kV electrostatic discharge without damage or memory loss.
- Power failure memory automatically restores lighting to the scene selected prior to power interruption.
- Faceplate snaps on with no visible means of attachment.
- Low-voltage type Class 2 (PELV) wiring connects Control Units, Wallstations, and Control Interfaces.
- Up to 8 Control Units may be linked to control up to 64 zones.
- Up to 16 total Wallstations and Control Interfaces may be added for a total of 24 control points.
- 32-104°F (0-40°C). Relative humidity less than 90% non-condensing.
| 24 V Direct Current | |||
| # of zones | Standard Setup Model # | PC Setup Model # | Wallbox U.S. Size |
| 2 | GRX-4102 | GRX-4502 | 2 Gang, 3.5" depth |
| 3 | GRX-4103 | GRX-4503 | 3 Gang, 3.5" depth |
| 4 | GRX-4104 | GRX-4504 | 4 Gang, 3.5" depth |
| 6 | GRX-4106 | GRX-4506 | 4 Gang, 3.5" depth |
| 8 | GRX-4108 | GRX-4508 | 4 Gang, 3.5" depth |
| 16 | GRX-4116 | GRX-4516 | 4 Gang, 3.5" depth |
| 24 | GRX-4124 | GRX-4524 | 4 Gang, 3.5" depth |
Top
GRAFIK Eye 4000 Series Slider Control Unit
- Controls up to 8 zones of lighting.
- Provides pushbutton recall of a single lighting scene.
- Stores up to 12 scenes that can be recalled using an optional Access Control.
- Includes default “panic” scenes (full-on)
- Allows full-range dimming plus slide-to-off using zone sliders.
- Provides a user-selectable Master Slider.
- Controls virtually any light source via dimming panels.
- Mounts in a standard U.S. wallbox.
- Control 3, 4, 6 or 8 zones of lighting.
- GRAFIK Eye Wallstations
- GP and LP Dimming Panels
Specifications
Power- Low-voltage type Class 2 (PELV) Operating voltage: 24VDC.
Controls lighting sources with a smooth, continuous Square Law dimming curve via GP and LP Dimming Panels.
Lighting Control- 12 user-programmable slider scenes plus 2 panic scenes and off.
- Light levels fade smoothly between scenes. Fade time can be set differently for each scene, between 0-59 sec. or 1-60 min. Fade time is not adjustable for panic scenes.
- Meets IEC 801-2. Tested to withstand 15kV electrostatic discharge without damage or memory loss.
- Power failure memory automatically restores lighting to the scene selected prior to power interruption.
- Faceplate snaps on with no visible means of attachment.
- Low-voltage type Class 2 (PELV) wiring connects Control Units, Wallstations, and Control Interfaces.
- Up to 8 Control Units may be linked to control up to 64 zones.
- Up to 16 total Wallstations and Control Interfaces may be added for a total of 24 control points.
- 32-104°F (0-40°C). Relative humidity less than 90% non-condensing.
Top
Faceplate Color and Finish Options
A variety of color and finish options are available for GRAFIK Eye 3000 and GRAFIK Eye 4000, to accent any décor. All GRAFIK Eye 3000 and 4000 units are available with a translucent top lid. All metal faceplates have a translucent top lid.
Architectural Matte

white
(WH)

beige
(BE)

ivory
(IV)

gray
(GR)

brown
(BR)

black
(BL)
Designer Gloss

white
(GWH)

light almond
(GLA)

almond
(GAL)

ivory
(GIV)
Satin Matte

midnight
(MN)

taupe
(TP)

snow
(SW)

eggshell
(ES)

biscuit
(BI)

limestone
(LS)

stone
(ST)

desert stone
(DS)

terracotta
(TC)

bluestone
(BG)

hot
(HT)

merlot
(MR)

sienna
(SI)

greenbriar
(GB)

sea glass
(SG)

mocha stone
(MS)

gold stone
(GS)

palladium
(PD)

plum
(PL)

turquoise
(TQ)
Standard Metal Finish

satin brass
(SB)

bright brass
(BB)

bright chrome
(BC)
Anodized Aluminum

clear anodized
(CLA)

black anodized
(BLA)

brass anodized
(BRA)
Special Metal Finish

antique brass
(QB)

antique bronze
(QZ)

satin chrome
(SC)

satin nickle
(SN)

bright nickle
(BN)
757.498.6118 Ext - 109, Or