Products
|
DCS SystemDownloads
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Specifications | |
| Operating Voltage | 24 V DC, -10/+30% |
| Operating Current | 25 mA to 65 mA |
| Operating Temperature Range | +5°C to +40°C |
| Dimensions (HxWxD) | 8.1 x 3.8 x 24.5 cm (3.2" x 1.5" x 9.6") |
| Weight | 0.2 kg (0.44 lbs) |
DCS 405R Extension Module
The module is used to provide connection to another DCS 400 rack frame and/or other DCS 400 boards. This is useful in situations where there are more cards on a given DCS 401R than a single DCS 400 frame can support.
Installation Notes
In the first DCS 400 rack frame the DCS 405R extension module always needs to be installed in the first empty slot.
In the DCS 400 extension unit - the second unit installed - the DCS 405R extension module always needs to be installed in slot 1.
| Specifications | |
| Operating Temperature Range | +5°C to +40°C |
| Dimensions (HxWxD) | 8.1 x 3.8 x 24.5 cm (3.2" x 1.5" x 9.6") |
| Weight | 0.12 kg (0.25 lbs) |
DCS 408R/409R Control Relay Modules
These modules provide relay contact closures for use in switching audio or other control functions. The 408R is capable of switching 70 V or 100 V speaker lines. The 409R is capable of switching line level audio signals or control outputs. The 408R can also be used to provide contact closures where higher voltages and/or current may be involved.
- 5 line relays, each with 2 switching contacts.
- Phoenix type connector for all contacts.
- 5 relay control-LEDs.
- Configuring the signal distributor is possible through separating wire-bridges.
- 12 DCS relay modules can be cascaded.
| Specifications | |
| Operating Voltage | 24 V DC, -10/+30% |
| Operating Current - relays off | 5.2 mA to 7.8 mA |
| Operating Current - all relays on | 55 mA to 130 mA |
| Operating Temperature Range | +5°C to +40°C |
| Dimensions (HxWxD) | 8.1 x 3.8 x 24.5 cm (3.2" x 1.5" x 9.6") |
| Weight | 0.2 kg (0.44 lbs) |
DCS 412R Logic Input Module
The module provides inputs for control lines, pushbuttons, switches and sensors, allowing the evaluation of their individual status (ON/OFF) in the DPM 4000 system.
- 12 inputs.
- Selectable polarity of each input.
- Floating inputs can be realized via the separation of wire bridges.
- Separate connections for power supplies of pushbuttons, contacts and sensors.
- Phoenix type connector for all inputs.
- Maximally 5 DCS412R/DCS412 modules can be cascaded.
| Specifications | |
| Operating Voltage | 24 V DC, -10/+30% |
| Operating Current - all inputs open | 2.6 mA to 8.2 mA |
| Operating Temperature Range | +5°C to +40°C |
| Voltage: LOW input | UIN < ±5 V |
| Voltage: HIGH input | UIN > ±10 V |
| Input Current @ UIN = 24V | IIN = 4.8 mA |
| Max. Input Volatage | UIN max = ±31 V |
| Output Voltage | 24 V DC |
| Max. Output Current | 90 mA |
| Dimensions (HxWxD) | 8.1 x 3.8 x 24.5 cm (3.2" x 1.5" x 9.6") |
| Weight | 0.2 kg (0.44 lbs) |
DCS 416R Analog I/O Module
The module provides analog input and output interfacing capabilities for use in monitoring and control functions. Both inputs and outputs are capable of handling 0 to 10 V DC with 256 distinct levels. Potentiometers for volume control can be interfaced using the provided reference voltage output.
- 8 analog inputs.
- Voltages of 0 to 10V DC or a potentiometer to each input.
- Output for reference voltage 10V DC.
- 8 analog outputs 0 to 10V DC.
- Phoenix type connector for all inputs and outputs.
- Maximally 2 DCS 416R / DCS 416 modules can be cascaded.
| Specifications | |
| Operating Voltage | 24 V DC, -10/+30% |
| Operating Current (max) | 160 mA |
| Operating Temperature Range | +5°C to +40°C |
| Inputs | |
| Voltage Range (min to max) | 0 V to 10 V DC |
| Impedance range Ext. (min to max) | 0 to 10 kΩ |
| Max. Input Volatage | 50 V DC |
| Outputs | |
| Voltage Range (min to max) | 0 V to 10 V DC |
| Output Impedance | 47 Ω |
| Max. Load | 2 kΩ |
| Resolution of Inputs/Outputs | 8-bit |
| Reference Output Voltage | 10 V DC |
| Reference Output Current | 30 mA (max) |
| Dimensions (HxWxD) | 8.1 x 3.8 x 24.5 cm (3.2" x 1.5" x 9.6") |
| Weight | 0.2 kg (0.44 lbs) |
DCS 420 Monitor Station
The DCS 420 Monitor Manager is a 2RU unit offering acoustic control and visual level metering of audio in the system. Switching and displaying of up to 250 audio signal sources, as well as, controlling the volume is carried out via front panel control switches.
The DCS 420 receives its audio feed from the monitor output of the DPM4000. DCS 420 system control functions are carried out through a connection to the DCS 401 controller module. The front panel controls of the DCS 420 offer audio level and line control switching of either the input signal or the output signal of the system amplifiers.
With several external sound sources connected, switching is performed through the DCS 409R module. When using remote-amplifiers, switching audio signals to the monitor bus is accomplished directly inside the amplifier. The signals are transmitted via remote interconnection cables.
757.498.6118 Ext - 109, Or